Oct-31 Ver. 5.4.32.0
'V8 series SYS PROG: version V2.000 '
'TS series SYS PROG: version V2.000 '
'S806 series SYS PROG: version V1.920 '
'V7 series SYS PROG: version V1.930 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
PLC Ladder transfer function added:
· Simens S7-300/400 MPI
Oct-13 Ver. 5.4.31.0
'V8 series SYS PROG: version V1.990 '
'TS series SYS PROG: version V1.990 '
'S806 series SYS PROG: version V1.920 '
'V7 series SYS PROG: version V1.930 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· FUJI MICREX-SX SPM/SPE supported.
· FUJI F□JF-R series supported.
· FUJI MICREX-SX SPH3000MM supported.
· FUJI F-MPC04E supported.
· MITSUBISHI L series(Built-in Ethernet)SPU device supproted.
· UNIPULSE F805A supported.
· SUS XA-A* supported.
· SAMSUNG SPC series supported.
· Panasonic FP7 supported.
· Panasonic FP7(Ethernet) supported.
TECHNOSHOT series: Trial period setting and upload prohibit setting added.
TECHNOSHOT series: Smooth Font supported.
V8 series: Alarm tracking: Acknowledge function extended.
V8 series: Switch: Repeat speed of calculation switch improved.
V8 series: Panasonic Network camera BB-HCM7xx series supported
V-SFT-5: Batch Change memory: Copy & Paste from Excel sheet supported (Mitsubishi PLC only).
V-SFT-5: Batch export/import of multi-language added.
V-SFT-5: List of the 3D bitmap area added.
V-SFT-5: Copy and Paste of [Multi-language] window added.

Jun-13 Ver. 5.4.30.0
'V8 series SYS PROG: version V1.950 '
'TS series SYS PROG: version V1.950 '
'S806 series SYS PROG: version V1.920 '
'V7 series SYS PROG: version V1.930 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· Ultra Instruments UIC CPU(MODBUS ASCII) supported.
· MITUBISHI Q series Multi-link2 Ethernet supported.

May-13 Ver. 5.4.29.0
'V8 series SYS PROG: version V1.950 '
'TS series SYS PROG: version V1.950 '
'S806 series SYS PROG: version V1.920 '
'V7 series SYS PROG: version V1.930 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V-SFT-5:Include all the parts files as a standard part packaging.

Apr-13 Ver. 5.4.28.0
'V8 series SYS PROG: version V1.950 '
'TS series SYS PROG: version V1.950 '
'S806 series SYS PROG: version V1.920 '
'V7 series SYS PROG: version V1.930 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· KEYENCE KZ series supported.
· RS Automation X8 series supported.
· RS Automation X8 series(Ethernet) supported.
· KOGANEI IBFL-TC supported.
· MODBUS ASCII supported.
· YOKOGAWA FA-M3V supported.
· YOKOGAWA FA-M3V(Ethernet) supported.
· YOKOGAWA FA-M3V(Ethernet ASCII) supported.
· XINJE XC series(MODBUS RTU) supported.
TECHNOSHOT supported.
PLC Ladder transfer function added:
· Simens!!S7-200 PPI
'V8 series: Change in 'Language' menu on the Main Menu screen '
'V8 series: 'Switch to Main Menu' function added. '
V-SFT-5: Windows8 32bit/64bit supported.
V-SFT-5: USB driver auto-installation supported.
V-SFT-5: Extended 3D parts included as standard parts files.

Jan-13 Ver. 5.4.27.0
'V8 series SYS PROG: version V1.920 '
'S806 series SYS PROG: version V1.920 '
'V7 series SYS PROG: version V1.920 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· Asahi Engineering Micro step driver D4730S supported.
· OMRON E5CK-T supported.
· Allen-Bradley CompactLogix L27ERM supported.
· MITSUBISHI QnU series CPU Higher rank model supported.
· Panasonic KW Series supported.
· FUJI FRENIC-HVAC/AQUA(MODBUS RTU) supported.
· OMRON PLC Multi Link2 compatible with V7 supported.
V8 series:Trend Graph/Trend Sampling Function extended.
V8 series:Language changeover function added to switch.
V8 series:Siemens: Filter Import Function of DB(Data Block) supported.
V8 series:Allen-Bradley: User Defined Tag Import Function supported.

Nov-12 Ver. 5.4.26.0
'V8 series SYS PROG: version V1.890 '
'S806 series SYS PROG: version V1.900 '
'V7 series SYS PROG: version V1.920 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
S806C: System Program fixed.

Oct-12 Ver. 5.4.25.0
'V8 series SYS PROG: version V1.890 '
'V7 series SYS PROG: version V1.920 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· Pnasonic MINAS A4 series supported.
· CHINO LT-400 Series supported.
· OMRON E5AK-T supported.
· FUJI WE1MA(Ver.B)(MODBUS RTU) supported.
· DeviceNet supported.
· KEYENCE KV3000 Multi-link2 with V7/V6-V8 supported.
FUJI ELECTRIC :
· Memory Conversion for when changing PLC model from MICREX-F to MICREX-SX supported.
MITSUBISHI :
· Tag Import function supported for the variable name CSV file exported by GX works2.
V8 Series : Recipe mode Filename Sorting function supported.

Jul-12 Ver. 5.4.24.0
'V8 series SYS PROG: version V1.830 '
'V7 series SYS PROG: version V1.920 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· Siemens TI500/505 supported.
· Siemens TI500/505 V4 Compatible supported.
· YAMATAKE MX series supported.
· Allen-Bradley PLC-5(Ethernet) supported.
· Orientalmotor High-efficiency AR Series(MODBUS RTU) supported.
· Orientalmotor CRK Series(MODBUS RTU) supported.
· RS OEMax NX700 Series(Ethernet) supported.
· JTEKT TOYOPUC(Ethernet PC10Mode) supported.
· SUNX LP-400 Supported commands extended.
V-SFT-5:Siemens: Tag Import Function supported.
V8 series:CC-Link Ver.2 supported.
Banner network camera supported.
Trend Function extended.
Mitsubishi: Ladder Monitor Function extended.
V810C: V609E compatible display function added. (128-color only).

Apr-12 Ver. 5.4.23.0
'V8 series SYS PROG: version V1.790 '
'V7 series SYS PROG: version V1.920 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· MITSUBISHI A link+Net10 supported.
· MITSUBISHI A series (OPCN-1) supported.
· OMRON SYSMAC C(OPCN-1) supported.
· FUJI ALPHA5 Smart(MODBUS RTU) supported.
· FUJI FePSU Breaker supported.
· FUJI FRENIC-MEGA SERVO(MODBUS RTU) supported.
· Siemens S5(PG port) supported.
· SHINKO TECHNOS ACD/ACR Series supported.
· SHINKO TECHNOS ACS-13A supported.
· SHINKO TECHNOS PC-900 supported.
· SHINKO TECHNOS PCD-33A supported.
· SHINKO TECHNOS WCL-13A supported.
· SHINKO TECHNOS GC Series supported.
· LS XGT/XGI series CPU supported.
· LS XGT/XGK series (Ethernet) supported.
· LS GLOFA GM7 CNET supported.
· GE Fanuc 90 series (SNP) supported.
· GE-Faunc RX3i(Ethernet TCP/IP) supported.
· FUFENG APC Series Controller supported.
MITSUBISHI PLC: KeepAlive supported.
OMRON PLC: KeepAlive supported.
V8 series: Japanese Conversion Function(FEP) extended.
V8 series: YOKOGAWA Ladder Monitor: Device Searching Function extended.
V8 series: YOKOGAWA Ladder Monitor: Function Block Switching extended.
V8 series: Modbus Slave (TCP/IP): The maximum of master devices expanded to 16.
V8 series: OMRON Ladder Monitor: CJ2 supported.
V-SFT-5: Text Search and Replacement Function added.
LadderComOp: Windows Vista/7 supported.

Jan-12 Ver. 5.4.22.0
'V8 series SYS PROG: version V1.750 '
'V7 series SYS PROG: version V1.920 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· OMRON E5CN-HT supported.
· TOSHIBA MACHINE TC200 Device added.
· VIGOR M series supported.
· LS XGT/XGI series supported.
· LS XGT/XGI series (Ethernet) supported.
· YOKOGAWA FA-M3/FA-M3R(Ethernet UDP/IP ASCII) supported.
· YOKOGAWA FA-M3/FA-M3R(Ethernet TCP/IP ASCII) supported.
V808C portrait orientation supported.
V-SFT-5: Filtering function for project view added.
V-SFT-5: Numerical data display parts on the panel meter change function added.

Oct-11 Ver. 5.4.21.0
'V8 series SYS PROG: version V1.720 '
'V7 series SYS PROG: version V1.910 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: versionV1.940 '
V8 series: PLCs newly supported.
· FUJI WSZ series supported.
· MITSUBISHI Q170MCPU (multi CPU) supported.
· MITSUBISHI Q170MCPU (multi CPU) (Ethernet) supported.
· Siemens S7-200(Ethernet ISOTCP) supported.
V8 series:
· Macro command search function added
· Panel meter functions available with 128 colors , 256 colors and monochrome type
· E-mail port No. change function added
· RGB (input) display compatible with V7
· V8 series: Windows font size in points available up to 999

Jul-11 Ver. 5.4.20.0
'V8 series SYS PROG: version V1.680 '
'V7 series SYS PROG: version V1.910 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V7 series: System Program fixed
· ' Please refer to Improvement Information for further information.'

Jun-11 Ver. 5.4.19.0
'V8 series SYS PROG: version V1.680 '
'V7 series SYS PROG: version V1.900 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V-SFT-5: Failure fixed

Apr-11 Ver. 5.4.18.0
'V8 series SYS PROG: version V1.670 '
'V7 series SYS PROG: version V1.890 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· YAMATAKE DMC50(COM) C Device supported.
· DELTA TAU DATA SYSTEMS PMAC P_INT Device supported.
· DELTA TAU DATA SYSTEMS PMAC(Ethernet TCP/IP) P_INT Device supported.
· YOKOGAWA FA-M3 SW/SL Extended Command supported.
· YOKOGAWA FA-M3R SW/SL Extended Command supported.
· YOKOGAWA FA-M3/FA-M3R(Ethernet UDP/IP) SW/SL/F Extended Command supported.
· YOKOGAWA FA-M3/FA-M3R(Ethernet TCP/IP) SW/SL/F Extended Command supported.
· YOKOGAWA FA-M3/FA-M3R(Ethernet UDP/IP) System-log read command supported.
· YOKOGAWA FA-M3/FA-M3R(Ethernet TCP/IP) System-log read command supported.
· YOKOGAWA FA-M3/FA-M3R the defult setting of Communication parameter changed.
· Universal Serial from PLC1 to PLC8 supported.
· Jetter JetControl Series2/3(Ethernet UDP/IP) supported.
· TOHO TTM-000 supported.
· Allen-Bradley NET-ENI(SLC500 Ethernet TCP/IP) supported.
· Allen-Bradley NET-ENI(Micrologix Ethernet TCP/IP) supported.
· Fuji Electric FALDIC-W series supported.
· GE Fanuc 90 Series(SNP-X) Multi Link2 compatible with V7 supported.
· SHARP JW300 series supported.
· SHARP JW series(Ethernet) supported.
· SHARP JW311/213/321/322(Ethernet) supported.
· SHARP JW331/332/341/342/352/362(Ethernet) supported.
· Fuji Electric MicrexSX Redundancy supported.
· KOYO SR-T(K Protocol) supported.
· KOYO SU/SG supported.
· GE Fanuc 90 series supported.
V7 series: PLCs newly supported.
· Fuji Electric MicrexSX T-Link Redundancy supported.
PLC Ladder transfer function added:
· MITSUBISHI QnA LadderMonitor supported
V8 series:
· Range after scaling numbers in Number Display reflected to Minimum and Maximum numbers.
· The function of printing Data Sheet extended.
V-SFT-5:
· The dialogue setting of MES reformed.
· The order INC of the Entry Target possible to be changed by Batch Change.
· Windows Vista/Windows 7 64bit supported.
· The addition of Attribute Specification Memory in Detail Tab of Number Display.
· The brightness adjusting Macro/ BRIGHT/ for V808CH supported.
· Tags of importing of Siemes S7-200 Format supported.

Feb-11 Ver. 5.4.17.0
'V8 series SYS PROG: version V1.650 '
'V7 series SYS PROG: version V1.880 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· YAMATAKE NX(CPL)
· YAMATAKE NX(Modbus RTU)
· YAMATAKE NX(Modbus TCP/IP)
· Agilent 4263 series
· Turck BL Series Distributed I/O (MODBUS TCP/IP)
· RKC FB100/FB400/FB900 (MODBUS RTU)
· MOELLER PS4
· FUJI FRENIC5000G11S/P11S
· FUJI PH series
· Allen-Bradley ControlLogix(Ethernet) CPU slot No. supported.
V8 series: Grobal Overlap supported.
V8 series: Additional features for a panel meter supported.
V8 series: Mute setting for Overlap buzzer supported.
V8 series: UPDATE function added to MES macro command.
V8 series: Backup making feature for Recipe function supported.
V8 series: Archive error log for wiring to external media supported.
V-SFT-5:
· Marging feature for the message supported.
· The limit of the number of the letters in a switch/lamp changed.

Nov-10 Ver.5.4.16.0
'V8 series SYS PROG: version V1.610 '
'V7 series SYS PROG: version V1.870 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V-SFT-5: Failure fixed

Oct-10 Ver.5.4.15.0
'V8 series SYS PROG: version V1.610 '
'V7 series SYS PROG: version V1.870 '
'V6 series SYS PROG: version V1.930 '
'V606e series SYS PROG: version V1.940 '
V8 series: PLCs newly supported.
· SANMEI CutyAxis
· OMRON SYSMAC CS1/CJ1 DNA
· OMRON SYSMAC CS1/CJ1 DNA(Ethernet)
· Siemens S7-1200(Ethernet ISOTCP)
· CIMON BP series
· CIMON CP series
· CHINO LT230(MODBUS RTU)
· CHINO LT300(MODBUS RTU)
· CHINO LT830(MODBUS RTU)
· CHINO DB1000B(MODBUS RTU)
· CHINO KR2000(MODBUS RTU)
· Bosch Rexroth IndraDrive
V7 series: PLCs newly supported.
· Siemens S7-1200(Ethernet ISOTCP)
· MITUBISHI QnU built-in Ethernet
V8 series: Continuous printing of data sheet printing supported.
V8 series: Float numbers supported for trend graph / trend sampling and data sampling.
V8 series: Add and delete for numbers supported for numeral entry.
V8 series: Offset memory supported for numeral data display and character display.
V-SFT-5:
· Remapping of the destination screen number supported for the switch function [screen].
· End memory designation and memory count designation supported for Memory batch change.

Jul-10 Ver.5.4.14.0
'V8 series SYS PROG: version V1.570 '
'V7 series SYS PROG: version V1.860 '
'V6 series SYS PROG: version V1.930 '
V8 series: PLCs newly supported.
· WAGO 750series(MODBUS RTU)
· WAGO 750series(MODBUS Ethernet)
· UNITORONICS Vision Series(ASCII Ethernet TCP/IP)
· HITACHI HIDIC-S10α
· MITSUBISHI QnU series(Built-in Ethernet)
· MITSUBISHI L series link
· MITSUBISHI L series (Built-in Ethernet)
V8 series: Remote Desktop: Auto reduction function enhanced.
V8 series: Operation Log: Filtered display of the log viewer added.
V8 series: Operation Log: Operation log can be selected with each switch.
V8 series: Yokogawa: Comment can be uploaded when using ladder monitor feature.
V8 series: Mitsubishi: Compatible memory device extended with Q series.
V8 series: Macro command: IF(TST) macro command added.
V8 series: Macro command: GRE_TO_CLND command added (converting date).
V8 series: Graphs: Float data supported.
V8 series: Total number to be registered is extended with Overlap Library/Screen Library/Page Block

Jun-10 Ver.5.4.13.0
'V8 series SYS PROG: version V1.560 '
'V7 series SYS PROG: version V1.850 '
'V6 series SYS PROG: version V1.930 '
V8 series: System Program fixed
· - The system program will be upgraded to Ver.1.560 due to the change of the flash memory which
is used in V8 series.

Apr-10 Ver.5.4.12.0
'V8 series SYS PROG: version V1.530 '
'V7 series SYS PROG: version V1.850 '
'V6 series SYS PROG: version V1.930 '
V7 series: System Program fixed
· #NAME?
· ' Please refer to Improvement Information for further information.'

Apr-10 Ver.5.4.11.0
'V8 series SYS PROG: version V1.530 '
'V7 series SYS PROG: version V1.840 '
'V6 series SYS PROG: version V1.930 '
V8 series PLCs newly supported.
· FUJI FVR-E11S
· M-SYSTEM R1M series(MODBUS RTU)
· OMRON KM20-B40
· OMRON KM100
V8 series: Panasonic network camera supported.
V8 series: Japanese Conversion Function - supported models extended.
V8 series:OMRON SYSMAC CS1/CJ1 USB/Ethernet ladder transfer function
V8 series: MODBUS RTU EXP Free Format
· maximum settable table number extended.
V8 series: Return switch - returning to the screen changed externally supported.
V8 series: PLC ladder monitor - supported function extended.
V8 series: PLC ladder monitor
· OMRON CJ1 supported.
V8 series: Multi-link2 compatibility with V7 supported.
V-SFT-5: Windows 7 supported.
V-SFT-5: Font size became changeable in Macro edit screen.
V-SFT-5: Comments in multiple lines supported in Macro edit screen
V-SFT-5: File name added to the title in Macro edit screen
V-SFT-5: Selection Environment Setting - Option to apply to all screens supported.
V-SFT-5: Option for auto-update of System Program (SYS PRG) supported.
Frame Auto Fit - right-click menu added to support the batch change of multiple parts.
V-SFT-5: Tag - usage list function supported.

Feb-10 Ver.5.4.10.0
'V8 series SYS PROG: version 1.520'
'V7 series SYS PROG: version 1.830'
'V6 series SYS PROG: version 1.930'
V8 series PLCs newly supported.
· GLOFA CNET
· GLOFA GM series CPU
· Allen-Bradley PLC-5
· MITSUBISHI MR-J2S-*A
· SHARP DS-30D
· SHARP DS-32D
· YASKAWA MP2000
· YASKAWA MP2000 series (Ethernet)
Trend Graph: Background drawing feature supported.
V-SFT-5: Import/export feature in Tag Database supported.
V-SFT-5: Memory/number remapping when moving screens supported.
V-SFT-5: Batch change of Screen Library supported.
V-SFT-5: Extended cross-reference feature supported.
V-SFT-5: export/import of Network Table supported

Nov-09 Ver.5.4.9.0
'V8 series SYS PROG: version 1.500'
'V7 series SYS PROG: version 1.820'
'V6 series SYS PROG: version 1.930'
V8 series PLCs newly supported.
· Automationdirect DirectLOGIC(Ethernet UDP/IP)
· IDEC MICRO Smart pentra
· TOSHIBA MACHINE VELCONIC series
· MODBUS RTU EXP Format

Oct-09 Ver.5.4.8.0
'V8 series SYS PROG: version 1.460'
'V7 series SYS PROG: version 1.800'
'V6 series SYS PROG: version 1.910'
V8 series: MITSUBISHI ladder monitor extensions.
V8 series: YOKOGAWA USB/Ethernet ladder transfer function supported.
V8 series: Symbol edit function supported.
V8 series PLCs newly supported.
· CHINO DP1000G
· IAI RCP2/ERC
· IAI RCS/E-CON
· FUJI ELECTRIC MicrexSX(SPH) Batch activation/stop supported.
· FUJI ELECTRIC FRENIC-MEGA(MODBUS RTU) Broadcast writing supported.
· FUJI ELECTRIC FRENIC-5000VG7S(MODBUS RTU) Broadcast writing supported.
· FUJI ELECTRIC FRENIC-Multi(MODBUS RTU) Broadcast writing supported.
· FUJI ELECTRIC FRENIC-Eco(MODBUS RTU) Broadcast writing supported.
· FUJI ELECTRIC PXG(MODBUS RTU) Port number is extended up to no. 247.
· FUJI ELECTRIC PXH(MODBUS RTU) Port number is extended up to no. 247.
· FUJI ELECTRIC PHR(MODBUS RTU) Port number is extended up to no. 247.
V-SFT-5: Macro symbol can be appeared on switch.
V8 series: 2-port supported with touchswitch emulation.
V8 series: Logout function supported in macro.
V8 series: Network camera AXIS M1011 supported.
V8 series: V7 compatible display in PAL supported.

Aug-09 Ver.5.4.7.0
'V8 series SYS PROG: version 1.460'
'V7 series SYS PROG: version 1.800'
'V6 series SYS PROG: version 1.910'
V8 series PLCs newly supported.
· MODICON ModbusRTU
· MITUBISHI MR-J3-*T
· SHIMADEN Shimaden Standard Protocol
· MODBUS RTU 1:n Multi-link2(Ethernet) supported.
· Telemecanique TSX Micro
· SHINKO TECHNOS JCx-300 series
· LS GLOFA GM series (Ethernet UDP/IP)
V8 series: RKC Setting range of the station number was extended

Jul-09 Ver.5.4.6.0
New model
· S808 series is added.
V8/V7/V6 series PLCs newly supported.
· MITUBISHI FX3 series (A Protocol) supported.
V8 series PLCs newly supported.
· MITUBISHI A series (CC-Link) supported.
· MITUBISHI QnA series (CC-Link) supported.
· GE Fanuc 90 series(Ethernet TCP/IP) supported.
· DELTA DVP series supported.
V8 series: Allen-Bradley: BOOL is supported forControl Logix/Compact Logix
V8 series: Modbus RTU: Data length of 7-bit is added.
'V8 series: 'Continuous buzzer' for switch supported.'
V-SFT-5: Macro tool bar added.
V-SFT-5: Batch setting of the Page block edit is supported.

May-09 Ver.5.4.4.0
V8series PLCs newly supported.
· MITSUBISHI FX3U-ENET supported.
· UNIPULSE F720A supported.
· UNIPULSE F800 supported.
· EMERSON EC10/20/20H (MODBUS RTU) supported.

Apr-09 Ver.5.4.3.0
V8 sereis: AB: Memory range extended from 65:255 to 255:255
Fuji: SX Instrumentation Package function supported.
V808C: V609E compatible display function added. (128-color only)
V8series PLCs newly supported.
· Hitachi Industrial Equipment System SJ300series supported.
· Hitachi Industrial Equipment System SJ700series supported.
· UNIPULSE F340A supported.
· UNIPULSE F371 supported.
· TOSHIBA EXseries supported.
· Banner Vision Ethernet I/P Protcol supported.
· MITSUBISHI QnH(Q)series (Ethernet ASCII) supported.
· MITSUBISHI QnH(Q)series (Multhi CPU) (Ethernet ASCII) supported.
· Siemens S7-200PPI: 187.5kbps supported.
V7/V6series PLCs newly supported.
· KEYENCE KV-3000/5000 supported.

Feb-09 Ver.5.4.1.0
V8 sereis: Remote Desktop function supported.
V8series PLCs newly supported.
· FL-Net supported.
  1. Hakko Driver Download For Windows 10 Laptop
  2. Hakko Driver Download For Windows 10 Free

ATI Radeon Display Driver 13.5 on 32-bit and 64-bit PCs. This download is licensed as freeware for the Windows (32-bit and 64-bit) operating system on a laptop or desktop PC from drivers without restrictions. ATI Radeon Display Driver 13.5 is available to all software users as a free download for Windows. Windows 10 64 bit, Windows 10, Windows 8.1 64 bit, Windows 8.1, Windows 8 64 bit, Windows 8, Windows 7 64 bit, Windows 7, Windows Vista 64 bit, Windows Vista, Windows XP Feb 3rd 2018, 09:15 GMT download. Windows 10 Compatibility If you upgrade from Windows 7 or Windows 8.1 to Windows 10, some features of the installed drivers and software may not work correctly.


ΔTop

USB/RS422 interface,adapter for Mitsubishi FX2N/FX1N/FX0/FX0S/FX1S/FX3U series PLC,2.5 meters,with communication indicator, the largest communication distance of up to 2 kilometers. Compatible with FX-USB-AW.
Summary:
USB-SC09-FX is the programming cable in which USB interface provided both the serial connection and RS232 signal conversion. Under the control of computer-driven driver, the programming cable makes it possible for the computer's USB interface to simulate the traditional serial (known as COM interface), thus various existing programming software such as communications software, monitoring software and other applications can be normally used. The working power supply of this cable is directly from the USB port, but not the PLC programming interface. The two-color LED on the converter box indicates data’s transceiving status.
USB-SC09-FX is applicable to the FX series PLC which has the MD8F radio socket of Mitsubishi, such as FX2N/FX1N/FX0/FX0N/FX0S/FX1S/FX3U, and it can substitute the FX-232AW module. The largest communications distance is two kilometers.
Do choose the USB-SC09 programming cable, for all FX series Mitsubishi PLC (including the old products FX2/FX2C).
Outline configuration:

Hakko driver download for windows 10 free

Features and technological index:
● Support USB-SC09-FX programming software version: FXGP / WIN V1.0, GPP V4.0, GX Developer V7.0 and above.
● Fully compatible with USB V1.1 norms and USB CDC V1.1
● USB-bus powered, with current consumption of 50 mA
● Baud rate: 300 bps ~ 1Mbps automatically adapt to the standard baud rate
● Support UART data format: data bits: 7-8; stop bit: 1, 2; check-bit: odd / even / no parity
● Support long-distance communications, the largest communications is two kilometers (9600 bps)
● Each PC only supports one USB cable programming
● Working temperature: -20 ~ +75 'C
● Cable length: 2.5m; Color: black
Usage:
USB device drivers should be installed before using USB-SC09-FX programming cable.
After completing Driver installation, the corresponding COM port for the USB-SC09-FX programming cable will be displayed in the “Device Manager” of Window. The step next is just to choose this COM port in the programming software and other application software and keep other communication parameters as in the Default settings. And the following steps are exactly the same as in the traditional programming cables with RS232 interfaces.

Download


Hakko Driver Download For Windows 10 Laptop

Long-distance communications:
the largest communications range between the USB-SC09-FXprogramming cable and the PLC is up to two kilometers (9600 bps).The user must follow the self-made plans to extend cable. Transmission Line should be 0.22mm2 or more, twisted pair wire. When the distance is over 2,000 m , RS422 repeater (model: E485GA)could be installed to extend the distance.
Please Note: USB interface cable cannot be extended.


Driver

Hakko Driver Download For Windows 10 Free

Hakko Driver Download For Windows 10

Due to internal resistance have been installed in USB-SC09-FX and the PLC, no external terminal resistance is needed.
The quality is guaranteed.It's tested before shippment.Not made by Mitsubishi,OEM product as the replacement